Description
The KPD (КПД) smoke exhaust fire damper is designed for supply and exhaust smoke-control ventilation systems of buildings and structures of various purposes, and for systems that remove smoke and gas after a fire from rooms protected by gas, aerosol or powder fire-extinguishing installations. It is applied in accordance with KMK 2.04.05. The damper consists of a casing, a rotary flap and an opening/closing mechanism; among other places, it is installed on branches of smoke or supply-air ducts. Circular and rectangular versions are made; the initial flap position is closed (normally closed, НЗ) and the function is smoke (Д). Actuator: electromagnetic (Э), reversible open/close electric actuator (ЭР) or spring-return electromechanical actuator without TRU (ЭМ1). Integrity (E) rating: E15 to E90 according to the catalogue text; the versions table lists KPD (60) — 1 h (E60) and KPD (90) — 1.5 h (E90). Working medium temperature -30 to +45 °C; climatic versions У and УХЛ, placement categories 3 and 4 per GOST 15150. Per the manufacturer's catalogue: rectangular section A×B from 150×150 to 1000×1000 mm, circular D from 200 to 710 mm; casing length 300 mm; weight from 10.67 to 86.5 kg. Standard and custom sizes can be made to the customer's order. Price on request — send a request and the supplier will reply with the price, lead time and delivery terms.
Specifications
- Type
- Smoke exhaust fire damper, normally closed (НЗ)
- Application
- Supply and exhaust smoke-control ventilation; post-fire smoke and gas removal
- Fire resistance
- E60 (1 h), E90 (1.5 h); catalogue text: E15 to E90
- Actuator
- Electromagnetic (Э), reversible electric (ЭР), spring-return electromechanical without TRU (ЭМ1)
- Power supply
- 220 V or 24 V
- Dimensions
- Rectangular A×B 150×150 to 1000×1000 mm; circular D 200–710 mm; length 300 mm
- Versions
- Circular and rectangular; duct, wall and nipple mounting; M1–M4; general-industrial (Н) and corrosion-resistant (К)
- Weight
- 10.67–86.5 kg
- Medium temperature
- -30 to +45 °C
- Operating conditions
- Climatic versions У, УХЛ; placement categories 3 and 4 per GOST 15150
- Standard
- КМК 2.04.05
- Designation (example)
- КПД-НЗ-Н-Е60-500x400-КН-НУП-ЭР-М2-1-СО-220
- Manufacturer
- JIHOZVENT, Tashkent (Uzbekistan)